How To Set Up A Distillation Apparatus
How do I set up distillation apparatus?
Quickfit glassware is incredibly handy when setting up experiments involving a lot of individual pieces and connections every bit the pieces come in a range of joint sizes that easily slot together for assembly. The range has hundreds of pieces including reduction and expansion adapters for when joint sizes do not match. On top of this, if y'all demand a custom piece and will be ordering sufficient quantities, Quickfit will be certain to be able to help.
We regularly get asked to provide a set up for unproblematic distillation and Quickfit have made this even simpler by producing an all in 1 Liebig condenser, still head, receiver slice for the set. It has 14/23 size socket and xix/26 size cones. This slice is easy to set up because all the angles and positions are predefined and its requires less clamping. At that place are less joints, which means if you grease your joints, there is less chance of contamination. You tin can read our other post here effectually alternatives to greasing the joints.
To complete your distillation gear up you will too need:
1.Thermometer Adapter
To fit the socket of the condenser, you will demand a thermometer adapter with a socket size of fourteen/23. Quickfit have two options for this piece, each suitable for differing diameters of thermometer.
- For thermometer diameter 6-7mm 1144215
- For thermometer bore vii-8.5mm 1144216
2.Thermometer
A thermometer should be placed then that it will measure the temperature of the gas every bit it is entering the outset of the condenser. It likewise needs to be positioned so that you can actually read off your temperature.
- Lox – toxicity lab thermometer range
three.Round Bottom Flasks
Circular bottom flasks can be used for both heating and collection. They come in a huge option of sizes and cervix lengths, although we recommend you volition demand to stick with the short neck length for this detail awarding. The cones on the all in one condenser are 19/26 and then you will need flasks with that size socket. A few different flask volumes can be found beneath:
- 5ml to 250ml flasks
If you lot are wanting to accurately measure out the volume of your condensate, and then we recommend that you collect it in a slice of volumetric glassware- such every bit a measuring cylinder.
four.Rubber tubing for water
This condenser has 13mm spiral thread inlets and outlets, meaning that it can attach ~9mm bore condom tubing. To connect upward with tubing, adhere 1 slice of tubing to the lower connector on the condenser, this is so continued to your tap. The upper connector of the condenser will attach tubing that runs into the drain. The flow of h2o, once the tap is turned on, will run from the bottom of the condenser, upward it, and out of the top connector and into the drain. Cold water running through your condenser makes it much more efficient allowing your collected vapour to condense more apace than if it were not h2o-cooled.
- Some appropriate rubber tubing is our standard rubber tubing – 1152535
5.Heating mantle
A heating mantle of an advisable size to friction match your humid flask is likewise required. There are two main types of heating mantle – controlled and uncontrolled. Controlled heating mantles have an in-built controller and so that you can change the temperature settings on the mantle itself. Uncontrolled mantles crave a carve up external controller. You can often connect up multiple mantles to 1 controller so if y'all are running a few of them at a time this may be a better pick. For this awarding even so, yous will nigh likely want to stick with a controlled mantle.
Some heating mantles too come up with a clamp on the back so that they tin can agree a retort rod in without the need to connect information technology to a base of operations.
See our recommendation below:
- CMU range of controlled heating mantles – this has a clench to hold a 13mm diameter antiphon rod.
6.Retort Stand and Clamps
Clamps are required to agree both your boiling flask and the condenser slice itself.
- Entire antiphon stand set up – 1177157
- 13mm diameter rod – 1137406
- Bosshead – 1149985
- Clamp – 1137412
We tin can supply the entire Quickfit range. If you need whatsoever aid in selecting the right pieces for your set up, delight email us at support@camlab.co.uk.